        what is IP5X and IP6X Ingress Protection Testing

        2025-08-01

        Dust Protected and Dust Tight (IP5X & IP6X)

        The degree of protection that an enclosure offers against invasions is tested through ingress protection testing. Solids or water can cause intrusions. Dust ingress testing is the smallest solid that is tested. To finish the IP Code dust testing, dust testing labs need to employ calibrated material.

        The IP Code specifies the level of dust protection. Two numbers are provided by the Ingress Protection IP testing. Protection from solids is represented by the first number. The defense against liquids is the second figure.

        The IP Codes IP5X and IP6X are the ones that were acquired from dust testing. The water resistance of the enclosure is indicated by the value of X in these codes, which goes from zero to nine. The initial number for dust-tight containers is 6, while the first number for enclosures that offer dust protection is 5.

        IP5X Dust Protected Enclosure

        The IP5X definition is given by IEC 60529, which is regarded as the IP5X standard. An enclosure that allows some dust to enter but not completely stops it is said to be dust-protected. These enclosures have an IP 5X dust protection rating.

        Dust cannot enter in enough to prevent the equipment from functioning satisfactorily in order for it to be deemed IP 5X test protected. Thus, in order to assert IP5X protection, the IP5X dust test necessitates an evaluation of the equipment activities.

        IP6X Dust Tight Enclosure

        A dust tight enclosure is defined as having a degree of protection where no ingress of dust. The ingress protection ratings for these enclosures are IP 6X dust tight. Unlike IP 5X dust testing, the IP 6X test requires no additional assessment as the presence of any dust in the enclosure is considered unacceptable.

        The enclosures have an IP Code of IP6X meaning it is dust tight and can have various degrees of water protection.

        IP5X and IP6X Ingress Protection Testing Laboratory Testing Procedures

        IP5X Testing:The level of protection against dust infiltration is evaluated using IP5X testing. The degree of protection against solid particles (dust) is indicated by the number "5" in IP5X. The following is how the test is conducted:

        Test Setup: A test chamber is filled with the equipment or product to be tested.

        Dust Application: Using a dust distributor or other tool, fine dust particles of a certain size are blasted towards the product from various angles. To guarantee consistency in the test, the dust particles employed for the experiment have a predetermined size.

        Test Duration: For a predetermined amount of time, the product is subjected to blowing dust.

        Evaluation: The product is inspected to see if any dust has gotten into the container and impacted its functionality after the exposure.

        IP6X Testing:

        The level of protection against the infiltration of dust, especially fine particles, is assessed using IP6X testing. In comparison to IP5X, the "6" in IP6X denotes a better level of protection against solid particles. The testing process entails the following procedures and is more rigorous:

        Test Setup: The product is put within a test chamber, much like in IP5X testing.

        Dust Application: The product is fully surrounded by a sizable volume of fine dust that has been placed into the test chamber and sized according to a predetermined standard.

        Test Duration: Typically longer than in IP5X testing, the product is subjected to the fine dust for a predetermined amount of time.

        Evaluation: Following the exposure period, the product is carefully examined to see if any dust has entered the enclosure and caused damage or affected its functionality.

        IP Dust and Water Resistance Evaluations

        As previously mentioned, enclosures are evaluated on their protection against solid objects and liquids. An example would be water and dust resistant IP68. In this case, the enclosure is dust tight. It also met the requirements for immersion beyond one meter.

        Another example is an enclosure that is IP67 water and dust resistant. The six represents dust tight. The seven represents immersion in water up to one meter. For a complete list of all of the possible IP5X ratings and IP6X ingress protection code combinations from IEC 60529, please see the chart at the bottom of this page.

        Below is a list of all of the IP5X and IP6X IP Code combinations along with a brief description of each test:

        IP50Dust protectedNot protected
        IP51Dust protectedDripping water
        IP52Dust protectedDripping water when tilted up to 15°
        IP53Dust protectedSpraying water
        IP54Dust protectedSplashing water
        IP55Dust protectedWater jets
        IP56Dust protectedPowerful water jets
        IP57Dust protectedImmersion up to 1 m
        IP58Dust protectedImmersion beyond 1 m
        IP59Dust protectedHigh-pressure and temperature water jets
        IP60Dust tightNot protected
        IP61Dust tightDripping water
        IP62Dust tightDripping water when tilted up to 15°
        IP63Dust tightSpraying water
        IP64Dust tightSplashing water
        IP65Dust tightWater jets
        IP66Dust tightPowerful water jets
        IP67Dust tightImmersion up to 1 m
        IP68Dust tightImmersion beyond 1 m
        IP69Dust tightHigh-pressure and temperature water jets

          

        SHENZHEN BONAD INSTRUMENT CO.,LTD, is a high-tech company in China, BONAD quality system has been strictly certified by ISO9001:2015. As a CIE Membership.

        Our main products are Test Equipment, Electrical Safety Tester, Environmental Chamber, Temperature Chamber, Climate Chamber, Thermal Chamber, Salt Spray Test, Dust Test Chamber, Waterproof Test, accessibility test probe and test finger, Glow Wire Test and Needle Flame Test,freezing load test package, soil moisture sensor, all kinds of gauges and so on.

        BONAD have gathered lots of experienced researchers and administrators on this field. BONAD products are manufactured strictly in accordance with various EN, IEC, CE, UL, VDE, VS, JIS, ISO, CEE, BS, FMV, GB and other similar international standards. All products can pass CE certificate and authenticated by the third party lab.

        Please feel free to contact us if you need any support.

        sales Dep:Alice@szbonad.com,

        Cell/WhatsApp:+8613380391156

        主站蜘蛛池模板: 国产一区二区三区小说| 日韩中文日韩中文字幕亚| 中文字幕亚洲日韩无线码| 高阳县| 成人午夜大片免费看爽爽爽| 亚洲av综合久久成人网| 欧美性群另类交| 性人久久久久| 国产精品免费观看色悠悠| 国色天香中文字幕在线视频 | 一本色道久久综合亚洲精品不卡| 亚洲av成人免费在线| 中文国产不卡一区二区| 97精品伊人久久久大香线蕉| 精品亚洲欧美无人区乱码 | 麻花传媒免费网站在线观看| 日韩在线视频线观看一区| 欧美日韩v| 一区二区三区av天堂| 男女性高爱潮免费网站| 亚洲国产成人不卡高清麻豆| 国产不卡av一区二区| 91福利一区福利二区| 国产成人精品一区二区秒拍1o| 亚洲精品第一国产综合精品| 无码乱人伦一区二区亚洲| 精品一精品国产一级毛片| 日韩三级一区二区在线看| 会同县| 亚洲国产精品综合色在线| 日本一区二区三区专线| 四虎成人免费视频在线播放| 4399理论片午午伦夜理片| 日日摸夜夜添夜夜添国产三级 | 亚洲69视频| 中文精品无码中文字幕无码专区| 午夜精品一区二区三区免费视频 | 少妇无码av无码一区| 2020年最新国产精品正在播放| 日韩精品中文女同在线播放| 国产中文字幕在线精品|